RENOGY  Battery Shunt 300 Renogy

RENOGY Battery Shunt 300

No
£64.00
Sale price  £64.00 Regular price  £92.00
Skip to product information
RENOGY  Battery Shunt 300 Renogy

RENOGY Battery Shunt 300

£64.00
Sale price  £64.00 Regular price  £92.00
Shipping calculated at checkout.
RSHST-B02P300-US
  • ✔ Premium Quality Materials
  • ✔ Quality Checked Before Dispatch
  • ✔ Secure Payments
  • ✔ Dedicated Customer Support
🚚

Fast Shipping

Quick dispatch and reliable delivery.

🔒

Secure Checkout

Your payments are protected and encrypted.

↩️

Easy Returns

Hassle-free return process.

⭐

Trusted Quality

Premium products loved by customers.

Payment methods
  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Klarna
  • Maestro
  • Mastercard
  • MB WAY
  • Shop Pay
  • Union Pay
  • Visa

Don't Forget To Explore More From This Collection

Customers often buy these together to complete their project.

Solar PV DC Combiner Box 5-In 1-Out 1000V IP65 | Voltacon
Solar PV DC Combiner Box 5-In 1-Out 1000V IP65 | Voltacon
£164.00
Add to Basket
AGM Battery Bank 8kWh 24V 200Ah 8x 6V Cells | Hoppecke
AGM Battery Bank 8kWh 24V 200Ah 8x 6V Cells | Hoppecke
£1,087.00
Add to Basket
Solar PV Combiner Box 6-In 2-Out 1000VDC IP65 | Voltacon
Solar PV Combiner Box 6-In 2-Out 1000VDC IP65 | Voltacon
£144.00
Add to Basket
Pylontech LV Hub 48V Battery Parallel Communication Hub
Pylontech LV Hub 48V Battery Parallel Communication Hub
£302.00
Add to Basket
Description
HOME
Check Your Battery Charging Level Anytime Anywhere
Ensures precise battery monitoring via the Renogy ONE Core and DC Home App.

 
Track Battery Data Performance Over Time.
In addition to real-time data monitoring, the battery Shunt 300 also helps record historical data via Renogy ONE Core and DC Home App, allowing you to make reasonable decisions about your entire power system.
 
Compatible With All Types of Batteries
The Shunt 300 is compatible with all your starter battery and main batteries, including lead acid (AGM, GEL), lithium iron phosphate, lithium-ion and nickel-metal hybrid.
Certified Performance
The Shunt 300 has undergone comprehensive testing to not only meet but also surpass exceptionally high standards of excellence.
Battery Temperature Sensor
Temperature sensors for batteries are indispensable for safety, longevity, efficiency, and data-driven decision-making in various applications.
Effortless Installation in 5 Minutes
It can be placed on top of the battery or securely mounted on the wall with screws. The connection points feature protective covers to effectively safeguard against any loosening caused by various movements.
 
Fast Connection in 4 Steps
When paired with Renogy ONE Core and DC Home, the Shunt 300 provides a seamless real-time data display experience.
 
Quick Setup Involves Simple Operations to Get Started
The initial steps for a quick setup are designed to be user-friendly and straightforward, ensuring that users can get started with ease.
 
Connect with Renogy customers.
Go to Power Plus Community
Still have questions?
Ask our specialist

Package Includes

Battery Shunt Only option
  • Battery Shunt 300 x 1
  • Quick Guide x 1
  • Mounting Screws x 3
  • B+ Wires (1 m) (22 AWG) × 2
  • Temperature Sensor (1.5 m) × 1
 
Battery Shunt 300
ELECTRICAL DATA

Model Name: RSHST-B02P300-G1

Power Supply: 8 - 120 VDC

Power Consumption: <0.1 W

Communication: Bluetooth LE and BLE Mesh

Max continuous current: 300A

Max peak current: 500A(<10s)

Current accuracy: ±1%

Current Resolution: 0.01 A

Battery Capacity: 1 - 6500Ah

Voltage Input Range: 8V to 120V DC

Voltage input resolution: 10 mV

Temperature sensor range: -20~80℃

Temperature sensor accuracy: ±1%

Operating Temperature: 14°F to 122°F (-10°C to 50°C)

Operating Humidity: 0% to 95% RH

Operating Altitude: Less than 2000m above sea level

Installation: Surface mounting

Battery connection: M10 bolts

Weight: 0.57lb (260g )

Dimensions: 5.27 x 3.82 x 1.22 inch (134 x 97 x 31 mm)

Warranty: 1-year material and workmanship warranty

Certifications: CE, FCC ID,IC ID,RCM,TSCA, RoHS,UN38.3,TELEC

 
1.In DC Home or Renogy ONE, the current is shown as negative when charging and positive when discharging.
 
Inspect for reverse contact on B- or Pterminals.
2. Incorrect temperature reading
 
Confirm the Battery Temperature Sensor is properly installed.
3. Incorrect SOC reading
 
The battery capacity decreases as the charging and discharging cycles increase.Re-configure the “Rated Battery Ah” to the capacity when the battery is fully charged.
4.Inaccurate sampling precision in large-current scenarios
 
Elevated ambient temperatures can affect sampling accuracy. Ensure proper ventilation for the shunt and remove the upper cover if needed.
5.What should I do if my Battery Shunt 300 is showing only discharging readings?
 
If you notice that your Battery Shunt 300 displays only discharging readings after installation, with the readings staying at zero, please follow these steps:
1.Remove Battery Shunt from both Renogy One Core and DC Home.
2. Uninstall the DC Home app and install a new DC Home app.
3. To avoid potential conflicts, turn off your phone before proceeding.
4.Set Renogy One Core to pairing mode and reset the Battery Shunt.
5.Pair Renogy One Core and Battery Shunt 300, then turn on your phone.
6.Activate pairing in DC Home; you will see a link, not the Battery Shunt 300 readings. However, this link is pairing Battery Shunt 300 and Renogy One Core with DC Home.
7. Pair this link.
By following these steps,you can resolve the issue, and the Battery Shunt 300 readings displayed correctly. If the issue persists, it's recommended to contact Renogy's technical support for further assistance.

 

6.Why does the SOC alarm parameter on my Battery Shunt reset to 50% in Renogy Core One settings?
 
If you're experiencing an issue where the State of Charge (SOC) alarm parameter you set for the Battery Shunt in Renogy Core One settings resets to 50% after a short period, follow these steps for troubleshooting:
1.Turn off the power to the Battery Shunt 300.
2.Delete the Battery Shunt 300 from the Renogy One Core settings.
3.Turn the power back on for the Battery Shunt 300.
4.Add the Battery Shunt 300 back to the Renogy One Core.
5.Refer to the user manual for the Battery Shunt 300 and follow the provided instructions for setting up the SOC alarm parameter.
By following these troubleshooting steps, you can resolve the issue of the SOC alarm parameter resetting to the default value.If the issue persists, it's recommended to contact Renogy's technical support for further assistance.

 

7.What should I do if my Battery Shunt 300 can connect to my phone but not to Renogy One Core?
 
If your Battery Shunt successfully connects to your phone but faces issues connecting to Renogy One Core, consider the following steps:
1.Check Renogy One Core Firmware
2.Reset the Battery Shunt 300:Press and hold the reset button on the Battery Shunt for 5 seconds until the Bluetooth light turns off.
3.Connection Steps:On the Renogy One Core, click "Add Device" and scan for the Battery Shunt 300.Once detected, the Battery Shunt's Bluetooth light should stay solid.
By following these troubleshooting steps, you can resolve issues related to Battery Shunt connectivity with the Renogy One Core. If problems persist, contact Renogy's technical support for further assistance.

 

8.Battery charge percentage doesn’t show and the Consumed Ah reading is way off.
 
If you encounter abnormal data readings on the Battery Shunt 300, follow these troubleshooting steps:
1.Power off the Battery Shunt 300 and restart it.
2.Perform charge and discharge cycles on the battery pack connected to the Battery Shunt 300.
3.After the restart and cycling, check if the consumed Ampere-Hours (AH) reading returns to normal.
If the issue persists after the above steps, please contact our support team for further assistance.

 

9.The Battery Shunt 300 doesn't have programming options for lithium or lead-acid batteries. Can it not be programmed for lithium or lead-acid batteries?
 
Battery Shunt 300 does not differentiate between battery types. Its calculations are based on current and voltage. During the initial connection, it will prompt you to input the battery capacity. It can also be manually calibrated. After fully charging the battery, set the current SOC to 100% in the settings.While specific programming for different battery types isn't available, these settings and manual adjustments ensure precise monitoring and control.
10.Can the Battery Shunt 300 handle battery banks larger than 300A?
 
The 300A specification of the Battery Shunt represents its maximum capacity rather than indicating a limitation based on battery bank size. It is not restricted to use only with 300A battery banks. To ensure compatibility, calculate the actual maximum continuous current in your circuit, and the Battery Shunt 300 should be suitable for monitoring larger battery banks.
More questions about your off-grid power system? Learn more from Renogy Learning Center!
 
 
Renogy Lycan 5000 Power Box
Renogy Lycan 5000 Power Box
 

 

Return policy

Our goal is for every customer to be totally satisfied with their purchase. If this isn't the case, let us know and we'll do our best to work with you to make it right.

Shipping

We will work quickly to ship your order as soon as possible. Once your order has shipped, you will receive an email with further information. Delivery times vary depending on your location.

Manufacturing

Our products are manufactured both locally and globally. We carefully select our manufacturing partners to ensure our products are high quality and a fair value.

You may also like