Victron Centaur Charger 12V/40A
Universal Input | Three Isolated Outputs | Multi-Stage Charging
The Victron Centaur Charger 12V/40A is a robust, high-performance battery charger designed for global use in demanding environments. This model, with MPN CCH012040000, provides a reliable 40 Amp charge for 12V battery banks, making it suitable for marine, automotive, off-grid, and industrial applications.
Engineered by Victron Energy, a renowned Dutch manufacturer, the Centaur range features a universal auto-ranging input (90-265VAC and 90-400VDC) ensuring full output power across the entire specified range, regardless of location. It incorporates a fully automatic three-stage charging characteristic to ensure optimal battery health and longevity.
KEY ADVANTAGE: Universal input voltage range (AC & DC) with full output power maintained.
Key Features
| ▶ Universal Input Voltage — Operates seamlessly on 90-265VAC (50/60Hz) and 90-400VDC, ideal for global use. |
| ▶ Three Isolated Outputs — Simultaneously charges up to three separate 12V battery banks, with each output capable of delivering the full rated current. |
| ▶ Three-Stage Charging — Features a fully automatic bulk, absorption, and float charge characteristic for optimal battery health and extended lifespan. |
| ▶ Temperature Compensation — An internal sensor adjusts charge voltage based on ambient temperature, preventing over or under-charging. |
| ▶ Durable Construction — Aluminium epoxy powder-coated cases with drip shield and stainless steel fixings ensure resilience in harsh environments. |
| ▶ Corrosion Resistance — Circuit boards are protected with an acrylic coating for maximum resistance against corrosion. |
| ▶ Battery Type Selection — DIP switches allow selection of optimal charge voltages for Flooded Lead-acid, Gel, or AGM batteries. |
Technical Specifications
| Parameter | Value |
|---|---|
| Product Model | Centaur Charger 12V/40A |
| Manufacturer Part Number (MPN) | CCH012040000 |
| Nominal Battery Voltage | 12V |
| Rated Charge Current | 40A |
| AC Input Voltage Range | 90-265VAC (50/60Hz) |
| DC Input Voltage Range | 90-400VDC |
| Number of Outputs | 3 (Isolated) |
| Charging Stages | 3-Stage (Bulk, Absorption, Float) |
| Battery Type Selection | Flooded, Gel, AGM |
| Safety Standards | EN 60335-1, EN 60335-2-29, UL 1236 |
| Emission Immunity Standards | EN 55014-1, EN 61000-3-2 |
| Automotive Directive Standards | EN 55014-2, EN 61000-3-3 |
Charging & Output Modes
The Victron Centaur 12V/40A charger employs an advanced three-stage charging algorithm to ensure batteries are fully charged and maintained without overcharging.
| Mode | Description |
|---|---|
| Bulk Charge | Delivers maximum current until the battery voltage reaches a pre-set level. |
| Absorption Charge | Maintains voltage while gradually reducing current, ensuring full charge without gassing. A 4-hour timer is initiated when output current drops to 70% of rated Amps. |
| Float Charge | Maintains a lower voltage to compensate for self-discharge, keeping the battery fully charged indefinitely. |
An internal temperature sensor provides automatic compensation of the charge voltage at –2 mV/ºC per cell, optimising charging performance across varying temperatures. DIP switches allow users to select specific charge/float voltages tailored for Flooded Lead-acid, Gel, or AGM battery types.
With three isolated outputs, this charger can simultaneously charge up to three separate battery banks, each receiving the full rated current, making it highly versatile for complex power systems.
Typical Applications
| Application | Description |
|---|---|
| Marine Vessels | Ideal for yachts, workboats, and recreational craft, charging engine start, service, and auxiliary battery banks. |
| RV & Campervans | Ensures leisure batteries are fully charged when connected to shore power or a generator. |
| Off-Grid Systems | Provides reliable AC or DC charging for battery banks in remote cabins or solar installations. |
| Industrial & Backup Power | Suitable for maintaining batteries in backup power systems, telecommunications, and industrial equipment. |
Built-In Protection Functions
The Victron Centaur Charger 12V/40A is equipped with integrated protection features to safeguard both the charger and connected batteries. Temperature sensors continuously monitor power components, automatically reducing output current under extreme environmental conditions to ensure operation within specified limits. The robust design, including epoxy powder-coated aluminium cases and acrylic-coated circuit boards, provides excellent resistance against heat, humidity, salt air, and general corrosion.
Common Questions
What battery types can this charger be used with?
The Victron Centaur Charger 12V/40A is compatible with Flooded Lead-acid, Gel, and AGM batteries. A DIP switch allows you to select the optimal charge/float voltages for your specific battery type.
Can it charge multiple battery banks simultaneously?
Yes, this charger features three isolated outputs, each capable of supplying the full rated current. This allows for simultaneous charging of up to three separate 12V battery banks.
What is the input voltage range for this charger?
The Centaur Charger has a universal auto-ranging input, accepting 90-265VAC (50/60Hz) and 90-400VDC. This wide input range ensures it can be used almost anywhere in the world without adjustment.
Is this charger suitable for marine environments?
Absolutely. The Centaur range is specifically designed for marine applications, featuring durable aluminium epoxy powder-coated cases, drip shields, stainless steel fixings, and acrylic-coated circuit boards to withstand heat, humidity, and salt air.
Installation Notes
- Installation should be carried out by qualified personnel in accordance with local electrical regulations and safety standards.
- Ensure adequate ventilation around the charger to prevent overheating, especially in enclosed spaces.
- Verify that all AC and DC wiring is correctly sized and fused for the charger's output and input current.
- Always disconnect AC power and battery cables before performing any maintenance or servicing.
- Select the correct battery type setting via the internal DIP switches to ensure optimal charging parameters for your specific batteries.
Before You Buy
- Confirm the nominal voltage of your battery bank(s) is 12V to ensure compatibility with this charger.
- Consider the total capacity of your battery bank(s) to ensure the 40A charge current is appropriate for efficient charging.
- Review the full product manual for detailed specifications, installation guidelines, and safety information.
- Ensure you have the necessary wiring, fuses, and tools for a safe and compliant installation.
Always verify product specifications and compatibility with your specific system requirements before purchase. Information is based on verified manufacturer data.
Return policy
Our goal is for every customer to be totally satisfied with their purchase. If this isn't the case, let us know and we'll do our best to work with you to make it right.
Shipping
We will work quickly to ship your order as soon as possible. Once your order has shipped, you will receive an email with further information. Delivery times vary depending on your location.
Manufacturing
Our products are manufactured both locally and globally. We carefully select our manufacturing partners to ensure our products are high quality and a fair value.