{"product_id":"victron-energy-lyn060102000-lynx-distributor","title":"Victron Energy LYN060102000 Lynx Distributor","description":"\u003c!-- eBay Listing: Victron Energy Lynx Distributor LYN060102000 --\u003e \u003c!-- eBay Compliant: No scripts, no external links, no Shopify tags, inline styles only --\u003e \u003cdiv style=\"font-family: Georgia, 'Times New Roman', serif; font-size: 16px; line-height: 1.7; color: #1a1a1a; max-width: 900px; margin: 0 auto; background-color: #ffffff;\"\u003e    \u003cdiv style=\"background-color: #0d2137; padding: 36px 24px; text-align: center; border-radius: 4px 4px 0 0;\"\u003e     \u003cdiv style=\"font-family: 'Courier New', Courier, monospace; font-size: 11px; letter-spacing: 4px; color: #f0a020; text-transform: uppercase; margin-bottom: 10px;\"\u003eVictron Energy Lynx Series\u003c\/div\u003e     \u003ch1 style=\"margin: 0; font-size: 24px; font-weight: 700; color: #ffffff; letter-spacing: 0.5px; line-height: 1.3;\"\u003eVictron Energy Lynx Distributor\u003c\/h1\u003e     \u003cp style=\"margin: 12px 0 0; font-size: 15px; color: #a8c4d8; font-style: italic;\"\u003eModular DC Busbar \u0026amp; Fuse Holder  |  LYN060102000  |  For 12V, 24V, 48V Systems\u003c\/p\u003e   \u003c\/div\u003e    \u003cdiv style=\"padding: 28px 24px; background-color: #f7f9fb; border-left: 1px solid #d8e4ee; border-right: 1px solid #d8e4ee;\"\u003e     \u003cp style=\"margin: 0 0 16px; font-size: 16px; color: #333;\"\u003eThe \u003cstrong style=\"color: #0d2137;\"\u003eVictron Energy Lynx Distributor (LYN060102000)\u003c\/strong\u003e is a crucial component for efficient and safe DC power distribution in various renewable energy systems, including solar, marine, and automotive applications. As a modular DC busbar with integrated fuse holders, it streamlines the organisation and protection of your DC electrical circuits.\u003c\/p\u003e     \u003cp style=\"margin: 0; font-size: 16px; color: #333;\"\u003eDesigned to be part of the Victron Lynx distribution system, this unit provides a centralised point for connecting and protecting up to four individual DC equipment circuits or loads. It features both positive and negative busbars, simplifying complex wiring setups. Each positive connection is equipped with a slot for a MEGA fuse, ensuring robust overcurrent protection for your valuable equipment.\u003c\/p\u003e     \u003cdiv style=\"margin-top: 20px; background-color: #0d2137; border-left: 5px solid #f0a020; padding: 14px 18px; border-radius: 0 4px 4px 0;\"\u003e       \u003cp style=\"margin: 0; color: #e8f0f8; font-size: 15px;\"\u003e\u003cstrong style=\"color: #f0a020;\"\u003eFUSE NOTE:\u003c\/strong\u003e The Lynx Distributor uses MEGA fuses, which are not supplied. For 48V systems, 58\/64V rated fuses are mandatory.\u003c\/p\u003e     \u003c\/div\u003e   \u003c\/div\u003e    \u003cdiv style=\"margin-top: 24px; padding: 24px; border: 1px solid #d8e4ee; background-color: #ffffff;\"\u003e     \u003ch2 style=\"margin: 0 0 16px; font-size: 14px; font-family: 'Courier New', monospace; letter-spacing: 3px; text-transform: uppercase; color: #0d2137; border-bottom: 2px solid #f0a020; padding-bottom: 8px;\"\u003eKey Features\u003c\/h2\u003e     \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e       \u003ctbody\u003e         \u003ctr\u003e\u003ctd style=\"padding: 9px 0; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003e▶  \u003cstrong\u003eModular DC Busbar\u003c\/strong\u003e — Seamlessly integrates into the Victron Lynx distribution system for expandable power setups.\u003c\/td\u003e\u003c\/tr\u003e         \u003ctr\u003e\u003ctd style=\"padding: 9px 0; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003e▶  \u003cstrong\u003eFour Fuse Holders\u003c\/strong\u003e — Provides dedicated overcurrent protection for up to four individual DC circuits or loads.\u003c\/td\u003e\u003c\/tr\u003e         \u003ctr\u003e\u003ctd style=\"padding: 9px 0; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003e▶  \u003cstrong\u003eFuse Status Indication\u003c\/strong\u003e — Onboard LEDs clearly show the condition of each fuse (blown or missing), enhancing safety and simplifying troubleshooting.\u003c\/td\u003e\u003c\/tr\u003e         \u003ctr\u003e\u003ctd style=\"padding: 9px 0; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003e▶  \u003cstrong\u003ePositive \u0026amp; Negative Busbars\u003c\/strong\u003e — Centralises DC power distribution and simplifies wiring for a cleaner installation.\u003c\/td\u003e\u003c\/tr\u003e         \u003ctr\u003e\u003ctd style=\"padding: 9px 0; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003e▶  \u003cstrong\u003eMEGA Fuse Compatibility\u003c\/strong\u003e — Designed for robust MEGA fuses, ensuring high current protection for demanding applications.\u003c\/td\u003e\u003c\/tr\u003e         \u003ctr\u003e\u003ctd style=\"padding: 9px 0; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003e▶  \u003cstrong\u003eRJ10 Communication\u003c\/strong\u003e — Includes a 40cm RJ10 cable for power and data connection to compatible Victron Lynx components.\u003c\/td\u003e\u003c\/tr\u003e         \u003ctr\u003e\u003ctd style=\"padding: 9px 0; font-size: 15px; color: #333;\"\u003e▶  \u003cstrong\u003eVictronConnect App Monitoring\u003c\/strong\u003e — When connected to a Lynx Smart BMS, allows monitoring and setup via the VictronConnect App.\u003c\/td\u003e\u003c\/tr\u003e       \u003c\/tbody\u003e     \u003c\/table\u003e   \u003c\/div\u003e    \u003cdiv style=\"margin-top: 24px; padding: 24px; border: 1px solid #d8e4ee; background-color: #f7f9fb;\"\u003e     \u003ch2 style=\"margin: 0 0 16px; font-size: 14px; font-family: 'Courier New', monospace; letter-spacing: 3px; text-transform: uppercase; color: #0d2137; border-bottom: 2px solid #f0a020; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h2\u003e     \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e       \u003cthead\u003e         \u003ctr style=\"background-color: #0d2137;\"\u003e           \u003cth style=\"padding: 10px 12px; text-align: left; font-size: 12px; letter-spacing: 1px; color: #f0a020; font-family: 'Courier New', monospace; font-weight: normal; text-transform: uppercase;\"\u003eParameter\u003c\/th\u003e           \u003cth style=\"padding: 10px 12px; text-align: right; font-size: 12px; letter-spacing: 1px; color: #f0a020; font-family: 'Courier New', monospace; font-weight: normal; text-transform: uppercase;\"\u003eValue\u003c\/th\u003e         \u003c\/tr\u003e       \u003c\/thead\u003e       \u003ctbody\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eModel\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003eLYN060102000\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eManufacturer\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003eVictron Energy\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eProduct Type\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003eDC Busbar \/ Distributor\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eNumber of Fuse Holders\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eFuse Type\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003eMEGA Fuses (not supplied)\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eNominal System Voltage\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003e12V, 24V, 48V\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eVoltage Range\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003e9 – 60V DC\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eContinuous Current Rating\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003e1000A\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eBusbar Connections (Module)\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003eM10\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eFuse \u0026amp; Cable Connections\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003eM8\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eEnclosure Material\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003eABS\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eProtection Class\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003eIP22\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eOperating Temperature\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003e-40°C to +60°C\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eDimensions (H x W x D)\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003e80 x 290 x 170 mm\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; font-size: 15px; color: #333;\"\u003eWeight\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; text-align: right; font-size: 15px; color: #333;\"\u003e\u003cstrong\u003e2.2 kg\u003c\/strong\u003e\u003c\/td\u003e         \u003c\/tr\u003e       \u003c\/tbody\u003e     \u003c\/table\u003e   \u003c\/div\u003e    \u003cdiv style=\"margin-top: 24px; padding: 24px; border: 1px solid #d8e4ee; background-color: #ffffff;\"\u003e     \u003ch2 style=\"margin: 0 0 16px; font-size: 14px; font-family: 'Courier New', monospace; letter-spacing: 3px; text-transform: uppercase; color: #0d2137; border-bottom: 2px solid #f0a020; padding-bottom: 8px;\"\u003eOperating \u0026amp; Power Guidance\u003c\/h2\u003e     \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e       \u003cthead\u003e         \u003ctr style=\"background-color: #1a3550;\"\u003e           \u003cth style=\"padding: 10px 12px; text-align: left; font-size: 12px; letter-spacing: 1px; color: #f0a020; font-family: 'Courier New', monospace; font-weight: normal; text-transform: uppercase;\"\u003eFunction\u003c\/th\u003e           \u003cth style=\"padding: 10px 12px; text-align: left; font-size: 12px; letter-spacing: 1px; color: #f0a020; font-family: 'Courier New', monospace; font-weight: normal; text-transform: uppercase;\"\u003eDetail\u003c\/th\u003e         \u003c\/tr\u003e       \u003c\/thead\u003e       \u003ctbody\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eFuse Monitoring Power\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eThe fuse status LEDs require a 5V power supply, typically provided by connecting to a Victron Lynx Shunt VE.Can or Lynx Smart BMS via the supplied RJ10 cable.\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eFuse Requirements\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eUses MEGA fuses. It is critical to select fuses with the correct voltage rating for your system; for 48V systems, 58\/64V rated fuses are mandatory.\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eSystem Integration\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eDesigned for modular integration with other Victron Lynx components, forming a continuous positive and negative busbar system.\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; font-size: 15px; color: #333;\"\u003eApp Monitoring\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; font-size: 15px; color: #333;\"\u003eWhen connected to a Victron Lynx Smart BMS, the Lynx Distributor's status can be monitored and configured using the VictronConnect App.\u003c\/td\u003e         \u003c\/tr\u003e       \u003c\/tbody\u003e     \u003c\/table\u003e   \u003c\/div\u003e    \u003cdiv style=\"margin-top: 24px; padding: 24px; border: 1px solid #d8e4ee; background-color: #f7f9fb;\"\u003e     \u003ch2 style=\"margin: 0 0 16px; font-size: 14px; font-family: 'Courier New', monospace; letter-spacing: 3px; text-transform: uppercase; color: #0d2137; border-bottom: 2px solid #f0a020; padding-bottom: 8px;\"\u003eTypical Applications\u003c\/h2\u003e     \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e       \u003cthead\u003e         \u003ctr style=\"background-color: #1a3550;\"\u003e           \u003cth style=\"padding: 10px 12px; text-align: left; font-size: 12px; letter-spacing: 1px; color: #f0a020; font-family: 'Courier New', monospace; font-weight: normal; text-transform: uppercase;\"\u003eApplication\u003c\/th\u003e           \u003cth style=\"padding: 10px 12px; text-align: left; font-size: 12px; letter-spacing: 1px; color: #f0a020; font-family: 'Courier New', monospace; font-weight: normal; text-transform: uppercase;\"\u003eDescription\u003c\/th\u003e         \u003c\/tr\u003e       \u003c\/thead\u003e       \u003ctbody\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eOff-Grid Solar Systems\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eProvides centralised DC distribution and robust fuse protection for battery banks, inverters, and various DC loads.\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eMarine \u0026amp; RV Installations\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eOrganises and protects onboard DC equipment, ensuring reliable power management in mobile environments.\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #ffffff;\"\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eIndustrial DC Systems\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; border-bottom: 1px solid #eee; font-size: 15px; color: #333;\"\u003eOffers reliable fuse protection and distribution for diverse DC applications in industrial settings.\u003c\/td\u003e         \u003c\/tr\u003e         \u003ctr style=\"background-color: #edf3f8;\"\u003e           \u003ctd style=\"padding: 9px 12px; font-size: 15px; color: #333;\"\u003eVehicle Electrics\u003c\/td\u003e           \u003ctd style=\"padding: 9px 12px; font-size: 15px; color: #333;\"\u003eFacilitates efficient power distribution for auxiliary power systems in commercial and recreational vehicles.\u003c\/td\u003e         \u003c\/tr\u003e       \u003c\/tbody\u003e     \u003c\/table\u003e   \u003c\/div\u003e    \u003cdiv style=\"margin-top: 24px; padding: 24px; border: 1px solid #d8e4ee; background-color: #ffffff;\"\u003e     \u003ch2 style=\"margin: 0 0 16px; font-size: 14px; font-family: 'Courier New', monospace; letter-spacing: 3px; text-transform: uppercase; color: #0d2137; border-bottom: 2px solid #f0a020; padding-bottom: 8px;\"\u003eBuilt-In Protection Functions\u003c\/h2\u003e     \u003cp style=\"margin: 0; font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe Victron Lynx Distributor incorporates essential protection features for enhanced system safety. It provides individual \u003cstrong style=\"color: #0d2137;\"\u003eMEGA fuse slots\u003c\/strong\u003e to protect connected DC circuits from overcurrents and short circuits. Additionally, \u003cstrong style=\"color: #0d2137;\"\u003evisual LED indicators\u003c\/strong\u003e on the front panel offer immediate feedback on the status of each fuse, turning red if a fuse is blown or missing, allowing for quick identification and resolution of issues. The unit also features \u003cstrong style=\"color: #0d2137;\"\u003ereverse polarity protection\u003c\/strong\u003e for the main busbar connections.\u003c\/p\u003e   \u003c\/div\u003e    \u003cdiv style=\"margin-top: 24px; border: 1px solid #d8e4ee;\"\u003e     \u003cdiv style=\"background-color: #0d2137; padding: 12px 20px;\"\u003e       \u003ch2 style=\"margin: 0; font-size: 14px; font-family: 'Courier New', monospace; letter-spacing: 3px; text-transform: uppercase; color: #f0a020; font-weight: normal;\"\u003eCommon Questions\u003c\/h2\u003e     \u003c\/div\u003e     \u003cdiv style=\"padding: 20px 24px;\"\u003e       \u003cdiv style=\"margin-bottom: 20px; padding-bottom: 20px; border-bottom: 1px solid #eee;\"\u003e         \u003cp style=\"margin: 0 0 6px; font-weight: 700; font-size: 15px; color: #0d2137;\"\u003eWhat type of fuses does the Lynx Distributor use?\u003c\/p\u003e         \u003cp style=\"margin: 0; font-size: 15px; color: #555; line-height: 1.6;\"\u003eThe Victron Lynx Distributor is designed to use MEGA fuses. These fuses are not included with the unit and must be purchased separately. It is crucial to select fuses with the correct voltage rating for your specific system, especially for 48V systems where 58\/64V rated fuses are required.\u003c\/p\u003e       \u003c\/div\u003e       \u003cdiv style=\"margin-bottom: 20px; padding-bottom: 20px; border-bottom: 1px solid #eee;\"\u003e         \u003cp style=\"margin: 0 0 6px; font-weight: 700; font-size: 15px; color: #0d2137;\"\u003eIs a Lynx Shunt required for the fuse LEDs to work?\u003c\/p\u003e         \u003cp style=\"margin: 0; font-size: 15px; color: #555; line-height: 1.6;\"\u003eYes, the Lynx Distributor's fuse indication LEDs require a 5V power supply. This power is typically provided by connecting the Distributor to a Victron Lynx Shunt VE.Can or a Lynx Smart BMS via the supplied RJ10 cable. Without this connection, the LEDs and fuse monitoring functions will not operate.\u003c\/p\u003e       \u003c\/div\u003e       \u003cdiv style=\"margin-bottom: 20px; padding-bottom: 20px; border-bottom: 1px solid #eee;\"\u003e         \u003cp style=\"margin: 0 0 6px; font-weight: 700; font-size: 15px; color: #0d2137;\"\u003eCan I monitor the Lynx Distributor with an app?\u003c\/p\u003e         \u003cp style=\"margin: 0; font-size: 15px; color: #555; line-height: 1.6;\"\u003eYes, if the Lynx Distributor is connected to a Victron Lynx Smart BMS, you can monitor its status and perform setup via the VictronConnect App. This provides convenient access to operational data and fuse status.\u003c\/p\u003e       \u003c\/div\u003e       \u003cdiv style=\"margin-bottom: 0; padding-bottom: 0; border-bottom: none;\"\u003e         \u003cp style=\"margin: 0 0 6px; font-weight: 700; font-size: 15px; color: #0d2137;\"\u003eWhat happens if not all fuse positions are used?\u003c\/p\u003e         \u003cp style=\"margin: 0; font-size: 15px; color: #555; line-height: 1.6;\"\u003eIf you are not using all four connection points, the corresponding fuse status LEDs may turn red, indicating a missing fuse. In such cases, fitting dummy fuses may be necessary to extinguish these red LEDs.\u003c\/p\u003e       \u003c\/div\u003e     \u003c\/div\u003e   \u003c\/div\u003e    \u003cdiv style=\"margin-top: 24px; padding: 24px; border: 1px solid #d8e4ee; background-color: #f7f9fb;\"\u003e     \u003ch2 style=\"margin: 0 0 16px; font-size: 14px; font-family: 'Courier New', monospace; letter-spacing: 3px; text-transform: uppercase; color: #0d2137; border-bottom: 2px solid #f0a020; padding-bottom: 8px;\"\u003eInstallation Notes\u003c\/h2\u003e     \u003cul style=\"margin: 0; padding-left: 18px; font-size: 15px; color: #444; line-height: 1.9;\"\u003e       \u003cli\u003eMount the Lynx Distributor in a dry, protected environment, ensuring adequate ventilation.\u003c\/li\u003e       \u003cli\u003eEnsure all DC connections are made with appropriately sized cables for the expected current loads.\u003c\/li\u003e       \u003cli\u003eAlways disconnect all power sources (batteries, chargers) before attempting installation or maintenance.\u003c\/li\u003e       \u003cli\u003eRefer to the official Victron Energy product manual for detailed installation instructions and wiring diagrams.\u003c\/li\u003e       \u003cli\u003eUse only MEGA fuses with the correct voltage and current ratings for each connected circuit.\u003c\/li\u003e     \u003c\/ul\u003e   \u003c\/div\u003e    \u003cdiv style=\"margin-top: 24px; padding: 24px; border: 1px solid #d8e4ee; background-color: #ffffff;\"\u003e     \u003ch2 style=\"margin: 0 0 16px; font-size: 14px; font-family: 'Courier New', monospace; letter-spacing: 3px; text-transform: uppercase; color: #0d2137; border-bottom: 2px solid #f0a020; padding-bottom: 8px;\"\u003eBefore You Buy\u003c\/h2\u003e     \u003cul style=\"margin: 0; padding-left: 18px; font-size: 15px; color: #444; line-height: 1.9;\"\u003e       \u003cli\u003eVerify compatibility with your existing or planned Victron Lynx system components, such as a Lynx Shunt or Lynx Smart BMS.\u003c\/li\u003e       \u003cli\u003eConfirm the required MEGA fuse ratings for your specific DC loads and system voltage. Fuses are sold separately.\u003c\/li\u003e       \u003cli\u003eConsider if fuse status indication is essential for your setup, as it requires connection to a compatible Lynx Shunt or Smart BMS.\u003c\/li\u003e       \u003cli\u003eEnsure you have sufficient space for the unit's dimensions (80 x 290 x 170 mm) and for proper cable routing.\u003c\/li\u003e     \u003c\/ul\u003e   \u003c\/div\u003e    \u003cdiv style=\"margin-top: 24px; padding: 18px 24px; background-color: #edf3f8; border: 1px solid #d8e4ee; border-radius: 0 0 4px 4px; text-align: center;\"\u003e     \u003cp style=\"margin: 0; font-size: 13px; color: #6a7f8a; font-style: italic;\"\u003eSpecifications are subject to change by the manufacturer. Always refer to the latest official Victron Energy documentation for precise details and installation guidelines. This product carries a 5-year manufacturer's warranty.\u003c\/p\u003e   \u003c\/div\u003e  \u003c\/div\u003e","brand":"SMG 26","offers":[{"title":"Default Title","offer_id":54909614129491,"sku":"792-LYN060102000","price":85.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1076\/9324\/4755\/files\/victron-energy-lyn060102000-lynx-distributor-solarika-co-uk_6a084c18-abcc-42c6-a3dc-8c56965083c7.jpg?v=1789040418","url":"https:\/\/progradewarehouse.com\/products\/victron-energy-lyn060102000-lynx-distributor","provider":"PRO GRADE WAREHOUSE","version":"1.0","type":"link"}