{"product_id":"schulz-srp-4010-air-compressor-460v","title":"Schulz Air Compressor SRP 4010 Dynamic 10 HP 120 Gallon Rotary Screw 460V 3 Phase","description":"\u003ch2\u003eSchulz SRP 4010 Dynamic — 10 HP Screw Compressor with an After-Cooler Fitted, 460 Volt\u003c\/h2\u003e\u003cp\u003eThe specification line worth finding on this model is \u003cstrong\u003eAfter Cooler: Yes\u003c\/strong\u003e. Plenty of screw compressors leave the factory without one, and the difference shows up in your shop rather than on the invoice. Compressed air leaves an air end hot and holding every bit of moisture it picked up from the room. Cool it at the machine and that water condenses where there is a drain waiting for it. Skip that step and it condenses further along instead — in your pipe runs, in your tools, in the regulator, and on whatever you were spraying.\u003c\/p\u003e\u003cp\u003eSo the SRP 4010 Dynamic is a 10 HP machine that is quietly better behaved than its size suggests: 35 CFM at 125 PSI, a continuous 100% duty cycle, an aluminium-bodied oil-injected screw air end, and a 120-gallon horizontal ASME receiver doing double duty as the chassis. This is the 460 Volt three-phase build.\u003c\/p\u003e\u003ch3\u003eWhat the after-cooler actually saves you\u003c\/h3\u003e\u003cp\u003eAir coming off a screw is warm, and warm air carries water in suspension. The instant it cools in a steel line it drops that water out as liquid. An after-cooler moves that event forward, into the machine, where the receiver and the drain can deal with it.\u003c\/p\u003e\u003cp\u003eThe practical results are unglamorous and worth money. Air tools live longer because their vanes and bearings are not being washed. Paint and powder work becomes repeatable rather than a gamble on the weather. Plasma consumables stop dying early. Steel pipework stops rusting from the inside and stops sending flakes downstream. None of this is a substitute for a dryer if your process needs genuinely dry air — the product data records no air dryer on this model — but it removes the bulk of the problem at source, and it makes any dryer you add later a much smaller one.\u003c\/p\u003e\u003ch3\u003e10 HP that behaves like more\u003c\/h3\u003e\u003cp\u003eComparing a screw to a piston machine on horsepower alone flatters the piston. A reciprocating unit is rated to run for a portion of each hour; the badge figure is a peak, not a plan. This air end is rated to run without stopping, so its 35 CFM at 125 PSI is a number you can build an air system around.\u003c\/p\u003e\u003cp\u003eThe aluminium body is the other half of the sizing story. It sheds heat readily, which is what a machine that never gets a rest period actually needs, and it keeps the whole assembly at 613 lbs rather than something a small shop cannot manoeuvre. Lubrication is oil-injected and the drive is belt, with a sight glass so the oil level is a look rather than a procedure.\u003c\/p\u003e\u003ch3\u003eLiving with it: noise, heat and the cabinet\u003c\/h3\u003e\u003cp\u003eThis is one of the enclosed models. The sound-attenuated cabinet holds the machine to 69 dB(A) — the difference between a compressor you site around and one you simply put somewhere. Schulz also publishes an ambient operating ceiling of 113 °F, so a hot roof space or an unconditioned back room is within its declared range rather than a gamble.\u003c\/p\u003e\u003cp\u003eThe cabinet earns its keep in a second, less obvious way: it keeps shop dirt off the cooler matrix and the belt. Anything that fouls a cooler on a machine with an after-cooler costs you the very benefit you bought it for, so a closed box is not just about noise here.\u003c\/p\u003e\u003ch3\u003eWill It Fit?\u003c\/h3\u003e\u003cp\u003eBecause the compressor is tank-mounted — the 2-in-1 arrangement — the whole installation is one object: 58.5\" long, 27.6\" wide, 39.8\" tall, 613 lbs. No separate receiver to site, no interconnecting pipework to have made.\u003c\/p\u003e\u003cp\u003eIt wants a flat, solid floor; a slab that dips under one corner will slowly rack the frame. Leave working room around the panels, both for cooling airflow and so that servicing does not turn into a furniture-moving exercise.\u003c\/p\u003e\u003cp\u003eThe electrical supply is 460 Volt three-phase. Schulz gives the amp draw and the recommended breaker as \"consult a certified electrician\" — not an evasion but the only defensible answer, because cable sizing follows your run length and your local code. Confirming supply, panel capacity and breaker before ordering is the customer's job, and it is what usually decides whether the machine runs the week it lands or the month after.\u003c\/p\u003e\u003ch3\u003eControl\u003c\/h3\u003e\u003cp\u003eA 24 Volt microprocessor controller manages operation, with adjustable parameters and a continuous readout that makes diagnosis possible instead of speculative. The starter is automatic and magnetic, with phase and sequence failure detection — the safeguard that stops a mis-phased supply spinning the air end backwards, which is a fast and expensive way to lose a screw unit.\u003c\/p\u003e\u003ch3\u003ePerfect For\u003c\/h3\u003e\u003cul\u003e \u003cli\u003e \u003cstrong\u003ePaint, powder and finishing work\u003c\/strong\u003e — moisture at the gun is the failure this model is built to reduce.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePlasma cutting and air-plasma tables\u003c\/strong\u003e, where wet air eats consumables.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eOne- to three-bay shops on 460 Volt three-phase\u003c\/strong\u003e wanting continuous-duty air without a large machine.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eExisting shops with steel pipework\u003c\/strong\u003e that has started shedding rust.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAnywhere the compressor shares a room with people\u003c\/strong\u003e, thanks to the enclosure.\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\u003cp\u003eA single factory-assembled unit: aluminium rotary air end, after-cooler, TEFC IP55 motor, magnetic starter with phase and sequence failure detection, 24 Volt microprocessor controller, sound-attenuated cabinet, 120-gallon horizontal ASME receiver, oil sight glass and a 3\/4\" tank outlet.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupplied separately:\u003c\/strong\u003e the data lists no air dryer and no electronic drain valve, so a manual drain routine or the equivalent hardware is on your list. Pipework, filtration, regulation and the electrical hook-up are not included.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ch4\u003eAir end and air treatment\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eType\u003c\/th\u003e \u003ctd\u003eRotary screw, oil-injected, belt drive\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePump material\u003c\/th\u003e \u003ctd\u003eAluminium\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAfter-cooler\u003c\/th\u003e \u003ctd\u003e\u003cstrong\u003eFitted\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e \u003ctd\u003e35 CFM at 125 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMax pressure\u003c\/th\u003e \u003ctd\u003e125 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eDuty\u003c\/th\u003e \u003ctd\u003eContinuous 100%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAir dryer\u003c\/th\u003e \u003ctd\u003eNot fitted\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eMotor, supply and control\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e \u003ctd\u003e10 HP, TEFC, IP55\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e \u003ctd\u003e460 Volt, 3-phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eControl circuit\u003c\/th\u003e \u003ctd\u003e24 Volt microprocessor controller\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e \u003ctd\u003eMagnetic, phase and sequence failure detection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAmps and breaker\u003c\/th\u003e \u003ctd\u003eGiven as \"consult a certified electrician\"\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eReceiver, size and environment\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e \u003ctd\u003e120-gallon horizontal, ASME certified, 2-in-1 tank-mounted\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e \u003ctd\u003e3\/4\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e \u003ctd\u003e58.5\" × 27.6\" × 39.8\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e \u003ctd\u003e613 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eSound level\u003c\/th\u003e \u003ctd\u003e69 dB(A)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAmbient ceiling\u003c\/th\u003e \u003ctd\u003e113 °F\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat the certification data does and does not say\u003c\/h3\u003e\u003cp\u003eThe receiver is ASME certified: the pressure vessel is built and stamped to a recognised code. On a tank held at 125 PSI in an occupied workshop that is the meaningful assurance, and it is the one the product data actually makes.\u003c\/p\u003e\u003cp\u003eIt makes no other. There is no record of an independent third-party listing covering the assembled machine — motor, starter, controller and enclosure evaluated as one product — and a vessel stamp does not stand in for that. We are not going to imply otherwise. If your insurer, your parent company's facilities standard or your local inspector requires that kind of listing for fixed electrical plant, raise it with us before ordering and we will confirm in writing what documentation exists today.\u003c\/p\u003e\u003ch3\u003eDelivery\u003c\/h3\u003e\u003cp\u003eFreight, palletised, anywhere in the lower 48 states, with the cost quoted live at checkout for your actual address instead of estimated.\u003c\/p\u003e\u003cp\u003eDecide how 613 lbs comes off the truck before you commit. Carriers deliver to the tailgate and no further, so a dock or forklift is the clean answer and a pallet jack is workable on flat, hard ground. Without either, book terminal pickup and take your own transport to the carrier's yard. Residential addresses are handled as residential deliveries and carry a residential fee. Schulz collection at Acworth, Georgia is also available.\u003c\/p\u003e\u003cp\u003eCheck the pallet over with the driver present and write any damage onto the bill of lading before signing — after a clean signature it is very hard to pursue.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cp\u003eA 12-month warranty applies, listed in the specification block as 1 Year consumer and 1 Year commercial.\u003c\/p\u003e\u003cp\u003ePlease leave a faulty unit assembled. A screw air end that has already been taken apart cannot be assessed for what went wrong first, and that is normally the end of the claim. Ring, text or message us on 866-774-7743, describe the behaviour, and let the machine be looked at whole.\u003c\/p\u003e","brand":"Schulz of America","offers":[{"title":"Default Title","offer_id":54965118566739,"sku":"970.3902-460","price":5468.0,"currency_code":"GBP","in_stock":true}],"url":"https:\/\/progradewarehouse.com\/products\/schulz-srp-4010-air-compressor-460v","provider":"PRO GRADE WAREHOUSE","version":"1.0","type":"link"}