{"product_id":"excel-power-xl-dyn-33s-30kva-single-phase-diesel-generator","title":"Excel Power XL-DYN-33S 30kVA Single Phase Diesel Generator","description":"\u003ch1\u003eExcel Power XL-DYN-33S 30 kVA Single Phase Diesel Generator\u003c\/h1\u003e \u003ch2\u003eOverview\u003c\/h2\u003e \u003cp\u003eThe Excel Power XL-DYN-33S is a heavy-duty, water-cooled diesel generator set delivering 30 kVA prime and 33 kVA standby power at 230 V, 50 Hz. With a Raywin 4-cylinder engine, Stamford alternator and a large 216 L base fuel tank, it is designed for reliable single-phase backup in homes, farms, workshops and light commercial premises where mains power cannot be taken for granted.\u003c\/p\u003e \u003cp\u003eRunning at a steady 1500 RPM with low noise levels of just 68 dB(A) at 7 m, the XL-DYN-33S offers a strong balance of output, longevity and acoustic performance in a compact packaged set.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003ePower output:\u003c\/strong\u003e 30 kVA \/ 30 kW (Prime), 33 kVA \/ 33 kW (Standby) at 50 Hz, 230 V.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eEngineered for reliability:\u003c\/strong\u003e Raywin 4F24TIG11 4-cylinder water-cooled diesel engine.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eProven alternator:\u003c\/strong\u003e Stamford S1L2-R alternator with class H insulation and IP23 protection.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eClean power delivery:\u003c\/strong\u003e Shunt excitation with ±1 % voltage regulation for stable output.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eQuiet operation:\u003c\/strong\u003e 68 dB(A) at 7 m in free field conditions.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHigh capacity tank:\u003c\/strong\u003e 216 L base fuel tank to support long runtimes (10.1 L\/hr at 100 % load).\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eEasy control:\u003c\/strong\u003e Deepsea DSE6120 control panel for monitoring, alarms and automatic operation.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFlexible connection:\u003c\/strong\u003e Hard-wired output plus sockets (1 × 16 A and 4 × 32 A).\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eWhere it works well\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eStandby power for larger homes, farmhouses and small commercial buildings.\u003c\/li\u003e \u003cli\u003eWorkshops and light industrial loads needing robust 230 V single-phase supply.\u003c\/li\u003e \u003cli\u003eIT, telecoms and critical single-phase systems needing dependable backup power.\u003c\/li\u003e \u003cli\u003eSites where low noise and larger single-phase capacity are important.\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eKey features\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eRaywin engine:\u003c\/strong\u003e 4F24TIG11 4-cylinder, 4-stroke, water-cooled diesel engine with electronic (ECU) governing.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eStamford alternator:\u003c\/strong\u003e S1L2-R alternator with single bearing, class H insulation and IP23 ingress protection.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eStable voltage:\u003c\/strong\u003e Shunt excitation and ±1 % voltage regulation to support sensitive loads.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow-noise package:\u003c\/strong\u003e Rated 68 dB(A) @ 7 m in free-field conditions.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eGenerous fuel capacity:\u003c\/strong\u003e 216 L base tank to match the 30 kVA output.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eComprehensive control:\u003c\/strong\u003e Deepsea DSE6120 controller for manual and automatic modes.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eFlexible output:\u003c\/strong\u003e Hard-wired connection plus 1 × 16 A and 4 × 32 A sockets.\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eOptional extras \u0026amp; upgrades\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eCoolant heater\u003c\/strong\u003e (for improved cold-weather starting).\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eBattery charger\u003c\/strong\u003e (to maintain starting battery on standby duty).\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eExternal fuel tank integration\u003c\/strong\u003e (for extended runtime beyond 216 L base tank).\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAutomatic Transfer Switches (ATS)\u003c\/strong\u003e (for automatic changeover between mains and generator).\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eRemote monitoring solutions\u003c\/strong\u003e (integration with site or building management systems).\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv style=\"border: 1px solid #eee; padding: 12px; border-radius: 8px; background: #fafafa; margin: 16px 0;\"\u003e \u003cstrong\u003eImportant:\u003c\/strong\u003e The generator must be installed, wired and commissioned by suitably qualified personnel. Before first start, always confirm engine oil, coolant and fuel levels in line with the manufacturer’s instructions.\u003c\/div\u003e \u003ch2\u003eTechnical specifications\u003c\/h2\u003e \u003ch3\u003eGenerating set\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eManufacturer\u003c\/td\u003e \u003ctd\u003eExcel Power\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eXL-DYN-33S\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOutput rating\u003c\/td\u003e \u003ctd\u003e50 Hz, 230 V, 1500 RPM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePrime power\u003c\/td\u003e \u003ctd\u003e30 kVA \/ 30 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStandby power\u003c\/td\u003e \u003ctd\u003e33 kVA \/ 33 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNoise level\u003c\/td\u003e \u003ctd\u003e68 dB(A) @ 7 m (free field conditions)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eConnection type\u003c\/td\u003e \u003ctd\u003eHard-wired \u0026amp; sockets (1 × 16 A + 4 × 32 A)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eEngine\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eMake \/ Model\u003c\/td\u003e \u003ctd\u003eRaywin \/ 4F24TIG11\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eGoverning type\u003c\/td\u003e \u003ctd\u003eECU \/ Electronic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCylinders \/ Arrangement\u003c\/td\u003e \u003ctd\u003e4 \/ In-line\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBore × Stroke\u003c\/td\u003e \u003ctd\u003e87 × 103 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplacement\u003c\/td\u003e \u003ctd\u003e2.45 L\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAspiration\u003c\/td\u003e \u003ctd\u003eNA (naturally aspirated)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCycle\u003c\/td\u003e \u003ctd\u003e4-stroke\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCompression ratio\u003c\/td\u003e \u003ctd\u003e19 : 1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCooling system\u003c\/td\u003e \u003ctd\u003eWater-cooling\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrequency \u0026amp; engine speed\u003c\/td\u003e \u003ctd\u003e50 Hz \u0026amp; 1500 RPM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eGross engine power (Prime)\u003c\/td\u003e \u003ctd\u003e37 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFuel consumption @ 100 % load\u003c\/td\u003e \u003ctd\u003e10.1 L\/hr\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eAlternator\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eMake \/ Model\u003c\/td\u003e \u003ctd\u003eStamford \/ S1L2-R\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNo. of bearings\u003c\/td\u003e \u003ctd\u003e1 (single bearing)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInsulation class\u003c\/td\u003e \u003ctd\u003eH\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIngress protection\u003c\/td\u003e \u003ctd\u003eIP23\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eExcitation system\u003c\/td\u003e \u003ctd\u003eShunt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage regulation\u003c\/td\u003e \u003ctd\u003e±1 %\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eControl panel\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eMake \/ Model\u003c\/td\u003e \u003ctd\u003eDeepsea \/ DSE6120\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFunctions\u003c\/td\u003e \u003ctd\u003eGenerator and engine monitoring, alarms, manual and automatic (AMF\/ATS) modes.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eDimensions \u0026amp; weight\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eLength × Width × Height\u003c\/td\u003e \u003ctd\u003e2280 × 1000 × 1500 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDry weight\u003c\/td\u003e \u003ctd\u003e1250 kg\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFuel tank capacity\u003c\/td\u003e \u003ctd\u003e216 L\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch2\u003eWhat’s in the box\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eExcel Power XL-DYN-33S diesel generator in acoustic canopy\u003c\/li\u003e \u003cli\u003eDeepsea DSE6120 controller pre-installed\u003c\/li\u003e \u003cli\u003eBasic user and installation documentation\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eWarranty \u0026amp; support\u003c\/h2\u003e \u003cp\u003eWarranty is typically 12 months or 1000 operating hours (whichever occurs first). Please check current terms at the time of order. Technical support and commissioning services are available on request.\u003c\/p\u003e \u003ch2\u003eInstallation \u0026amp; compliance notes\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eInstall on a level, well-ventilated surface with adequate clearance for cooling and service access.\u003c\/li\u003e \u003cli\u003eAll electrical work must be carried out by a competent, qualified electrician.\u003c\/li\u003e \u003cli\u003eUse an appropriately rated \u003cstrong\u003eATS\u003c\/strong\u003e if automatic mains\/generator changeover is required.\u003c\/li\u003e \u003cli\u003eProvide correct earthing, over-current and RCD protection in accordance with local regulations.\u003c\/li\u003e \u003cli\u003eUse suitable diesel fuel and verify oil and coolant levels before first start.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eDocuments for Download\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0579\/7927\/3414\/files\/XL-DYN-33S-30kVA-1-Phase-Rental-Datasheet-1.pdf?v=1763217885\"\u003eExcel Power XL-DYN-33S 30kVA Single Phase Diesel Generator Datasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"Excel Power","offers":[{"title":"Default Title","offer_id":54909190242643,"sku":"XL-DYN-33S","price":5179.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1076\/9324\/4755\/files\/Excel-Power-XL-DYN-33S-30kVARight-View-Angle-1100x1100.webp?v=1789038728","url":"https:\/\/progradewarehouse.com\/products\/excel-power-xl-dyn-33s-30kva-single-phase-diesel-generator","provider":"PRO GRADE WAREHOUSE","version":"1.0","type":"link"}