{"product_id":"earth-fault-protection-aerl-aerl-earthguard-ground-fault-detection","title":"Earth Fault Protection | AERL | EarthGuard Ground Fault Detection EG-300","description":"\u003ch6 data-mce-fragment=\"1\"\u003eDescription\u003cbr data-mce-fragment=\"1\"\u003e \u003c\/h6\u003e \u003cp\u003e\u003cstrong\u003eAERL EarthGuard Ground Fault Detection - EG-300\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eUtilizing proprietary detection techniques, the AERL EarthGuard Insulation Monitoring Device simultaneously monitors the unearthed PV Array (60 - 300V) and Battery Storage System (48\/120V) for conductor insulation degradation.\u003cbr\u003e\u003cbr\u003eInstalled on the battery bus, the EarthGuard monitoring device satisfies the earth fault detection requirements of both AS\/NZS 5033:2014 \u0026amp; AS\/NZS 5139:2019 with onboard audio\/visual alarms and an alarm relay output for external fault indication.\u003cbr\u003e\u003cbr\u003eFeaturing support for full integration with AERL’s CoolMax SRX charge controller range, EarthGuard can be utilized in an integrated arrangement or as a standalone device for use with approved third-party controllers, power conversion equipment\u003cbr\u003eand battery systems.\u003c\/p\u003e \u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e \u003ch6 data-mce-fragment=\"1\"\u003eSpecifications\u003c\/h6\u003e \u003ctable style=\"width: 101.491%;\" data-mce-fragment=\"1\"\u003e \u003ctbody data-mce-fragment=\"1\"\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e1.2 kg\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eDimensions (L x W x H)\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e140 x 230 x 110 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eEnclosure Type\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003eIndoor Type 1 \/ IP20\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eOperating Temperature\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e-25 to 60°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eStorage Temperature\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e-25 to 80°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eConnection Terminals\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003eScrewless Terminals (0.25 mm2 -\u0026gt; 5.25 mm2 )\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eInput Power (12V Input)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003e10 – 14 Vdc (12V Nominal)\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eMax Power Consumption (12V Input)\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e120mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eInput Power (5V Input – USB C)\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e4.5 – 5.5 Vdc (5V Nominal)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eMax Power Consumption (5V Input)\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e290mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eAlarm Indication Relay\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003eSignal (Dry Contact)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003ePV Array Monitoring Range \u003c\/strong\u003e\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003e60 – 300 Vdc \u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003eSupported Battery Voltages\u003c\/strong\u003e\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e\u003cstrong\u003e48 Vdc | 120 Vdc\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eInput Load Under Test\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e0.5 Mohm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eInput Load Not Under Test\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e300 Mohm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eLeakage Trip Current (+\/-10%)\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e\u0026gt; 80uA | \u0026gt; 210uA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eIsolation to Low Voltage Side\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003e1000V (Transient)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eElectrical Safety\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003eAS\/NZS 3100:2017\u003c\/td\u003e \u003c\/tr\u003e \u003ctr data-mce-fragment=\"1\"\u003e \u003ctd style=\"width: 46%;\" data-mce-fragment=\"1\"\u003eEMC (Domestic)\u003c\/td\u003e \u003ctd style=\"width: 51.4908%;\" data-mce-fragment=\"1\"\u003eAS\/NZS 61000.6.3:2012\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp data-mce-fragment=\"1\"\u003ePlease see more details in the 'Data Sheets' tab.\u003c\/p\u003e \u003ch6 data-mce-fragment=\"1\"\u003eDelivery\u003c\/h6\u003e \u003cp data-mce-fragment=\"1\"\u003e\u003cmeta charset=\"utf-8\"\u003eAll items subject to availability and will generally require a 4-6 week turnaround.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e \u003cp data-mce-fragment=\"1\"\u003eWe don't hold the stock on hand but have a trusted supplier who will send this direct from their nearest warehouse to ensure you receive it as soon as possible.\u003c\/p\u003e \u003ch6 data-mce-fragment=\"1\"\u003eWarranty\u003c\/h6\u003e \u003cp\u003eOur goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. AERL will bear the cost of parts and labour to repair any manufacturing faults found within the terms and period of this warranty. For claims under warranty, the faulty product(s) must be returned to AERL’s facility at 2\/75 Bluestone Cct, Seventeen Mile Rocks, Brisbane, Australia after contacting AERL and receiving the appropriate RMA documentation from AERL. No allowance is made for labour or travelling time required to disconnect or reinstall faulty parts. AERL will pay the cost of freight to return the repaired charge controller to the customer within Australia or New Zealand only. Any faults or like faults caused by lightning, water or moisture ingress, vermin infestation, improper voltage, faulty installation, use of the product in a manner for which it is not intended, alterations which affect the reliability or performance of the unit but are not attributable to faulty manufacture, failure to act on service warning from the AERL charge controller, or damage caused by other system components will not be covered under warranty.\u003c\/p\u003e \u003cp\u003eRegister your warranty\u003cspan\u003e \u003c\/span\u003e\u003ca class=\"js-no-transition\" title=\"AERL Product Warranty Registration\" href=\"https:\/\/www.aerl.com.au\/activate-warranty\/\" target=\"_blank\"\u003e\u003cstrong\u003ehere\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca class=\"js-no-transition\" title=\"AERL Limited Warranty Policy\" href=\"https:\/\/www.aerl.com.au\/wp-content\/uploads\/2018\/06\/CoolMax-SRX-Warranty-Conditions.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eAERL Limited Warranty Policy\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e \u003ch6 data-mce-fragment=\"1\"\u003eData Sheets\u003c\/h6\u003e \u003cp data-mce-fragment=\"1\"\u003ePlease see \u003c\/p\u003e \u003cp\u003e\u003ca class=\"js-no-transition\" href=\"https:\/\/www.aerl.com.au\/wp-content\/uploads\/2020\/10\/EarthGuard-Datasheet-REV-1.2.pdf\" title=\"AERL EarthGuard Spec sheet\" target=\"_blank\"\u003e\u003cstrong\u003eData sheet here\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca class=\"js-no-transition\" title=\"AERL EarthGuard Manual\" href=\"https:\/\/www.aerl.com.au\/wp-content\/uploads\/2020\/10\/EarthGuard-300-User-Manual-REV-1.2.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eManual here\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca class=\"js-no-transition\" href=\"https:\/\/www.aerl.com.au\/wp-content\/uploads\/2020\/05\/EarthGuard-Warranty-Conditions.pdf\" title=\"AERL EarthGuard Warranty guide\" target=\"_blank\"\u003e\u003cstrong\u003eWarranty guide here\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e\u003ca class=\"js-no-transition\" title=\"Do I need an AERL EarthGuard?\" href=\"https:\/\/www.aerl.com.au\/do-i-need-an-earthguard\/\" target=\"_blank\"\u003e\u003cstrong\u003eDo I need an EarthGuard? Here\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"AERL","offers":[{"title":"Default Title","offer_id":55055731229011,"sku":"EG-300","price":361.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1076\/9324\/4755\/files\/AERLEARTHFAULT.png?v=1790332014","url":"https:\/\/progradewarehouse.com\/products\/earth-fault-protection-aerl-aerl-earthguard-ground-fault-detection","provider":"PRO GRADE WAREHOUSE","version":"1.0","type":"link"}