{"product_id":"champion-hrv10-12-air-compressor","title":"Champion Air Compressor HRV10-12 10 HP 120 Gallon 3 Phase","description":"\u003ch2\u003eChampion HRV10-12: the mid-size shop compressor, lying down\u003c\/h2\u003e \u003cp\u003eBetween the compressor that cannot keep up and the one that costs more to install than to buy, there is a size most working shops actually need. The HRV10-12 sits there: \u003cstrong\u003e34 CFM\u003c\/strong\u003e at \u003cstrong\u003e175 PSI\u003c\/strong\u003e, produced by a \u003cstrong\u003e10 HP\u003c\/strong\u003e motor turning at \u003cstrong\u003e1,800 RPM\u003c\/strong\u003e, stored in a \u003cstrong\u003e120-gallon\u003c\/strong\u003e receiver that lies horizontally along a \u003cstrong\u003e71\"\u003c\/strong\u003e run.\u003c\/p\u003e \u003cp\u003eHorizontal is the point of this variant. Standing the same volume of tank upright buys back floor but costs headroom, and plenty of buildings — basements, workshops under a mezzanine, bays with a low roll-up door track — cannot pay in headroom at any price. This is the version of the RV package for those rooms.\u003c\/p\u003e \u003cp\u003eIt arrives as a packaged simplex unit with the magnetic NEMA 1 starter already mounted, so what you are scheduling is an electrical connection, not an assembly job.\u003c\/p\u003e  \u003ch3\u003eIs 34 CFM the right size for you?\u003c\/h3\u003e \u003cp\u003eThe honest way to size a compressor is to count the tools that genuinely run at the same time, not the tools you own. Two technicians with impact tools and a blow gun are intermittent draws; a sander, a die grinder or a cut-off tool run continuously and are what actually empties a tank. \u003cstrong\u003e34 CFM\u003c\/strong\u003e comfortably covers a two-to-three bay service shop with mixed work, and it starts to feel tight the moment two continuous-draw tools run all day alongside everything else.\u003c\/p\u003e \u003cp\u003eThe \u003cstrong\u003e120-gallon\u003c\/strong\u003e receiver is what makes that number liveable. Reserve does not make air, but it flattens the peaks so the pump cycles less often and the pressure at the far end of the shop holds steadier when several people reach for a tool at once. A big tank on a moderate motor is a deliberate design, not a compromise.\u003c\/p\u003e  \u003ch3\u003eWhere you put it, and how loud it is there\u003c\/h3\u003e \u003cp\u003eReciprocating compressors are not quiet, and the two features that address it are easy to skim past. An intake filter and silencer handles the induction noise — the hard, rhythmic bark a compressor makes drawing air — and an enclosed belt guard covers the drive. Neither turns it into a background appliance, but together they change what it sounds like through a wall.\u003c\/p\u003e \u003cp\u003eSiting matters more than either. A horizontal unit like this sits low and stable, which makes it easier to put along a back wall or behind a partition than a tall upright of the same volume. Keep air on all sides regardless: the pump is air-cooled, and a compressor tucked into a tight nook runs hotter, which shortens oil life before it shortens anything else.\u003c\/p\u003e  \u003ch3\u003eWill It Fit?\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eWall run.\u003c\/strong\u003e \u003cstrong\u003e71\"\u003c\/strong\u003e long, plus working clearance for oil changes, belt access and the safety valve.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHeight.\u003c\/strong\u003e Our data records an overall height for this model as a bare number with no unit written beside it, so no clearance figure is printed here. That is a genuine gap and not a small one on a machine bought for a low room — ask us and we will confirm it against the factory drawing before you order.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSupply.\u003c\/strong\u003e Listed for \u003cstrong\u003e208 \/ 230 \/ 460 \/ 575V\u003c\/strong\u003e three-phase. The voltage is fixed when the order is placed, so settle it with us and your electrician first.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHandling.\u003c\/strong\u003e \u003cstrong\u003e895 lbs\u003c\/strong\u003e crated. Plan the offload and the route to its resting place before the truck books in.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eAir connection.\u003c\/strong\u003e \u003cstrong\u003e3\/4\"\u003c\/strong\u003e tank outlet. Size the shop main for the tools at the end of it, not for the fitting at the start.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eYour responsibility.\u003c\/strong\u003e Slab, electrical supply, permits, offload and placement are all for the buyer to arrange.\u003c\/li\u003e \u003c\/ul\u003e  \u003ch3\u003ePerfect For\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eTwo and three-bay service shops\u003c\/strong\u003e with mixed air-tool work through the day.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eLow-ceiling buildings\u003c\/strong\u003e where an upright receiver of the same volume simply will not stand up.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eTyre, exhaust and general repair work\u003c\/strong\u003e that needs steady \u003cstrong\u003e175 PSI\u003c\/strong\u003e rather than peak output.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eShops replacing a tired single-stage unit\u003c\/strong\u003e and wanting the starter and controls to arrive fitted.\u003c\/li\u003e \u003c\/ul\u003e  \u003ch3\u003eWhat's in the Box\u003c\/h3\u003e \u003cp\u003eA packaged simplex machine: the RV30 pump, the \u003cstrong\u003e10 HP\u003c\/strong\u003e motor at \u003cstrong\u003e1,800 RPM\u003c\/strong\u003e, the horizontal \u003cstrong\u003e120-gallon\u003c\/strong\u003e ASME coded receiver, a mounted NEMA 1 magnetic starter as standard, tank-mounted start\/stop pressure switch control, intake filter and silencer, enclosed belt guard and loadless starting. There is no air dryer fitted and no electronic drain valve fitted; if your work needs dry air, that is a conversation to have before the order rather than after the first water in a paint line.\u003c\/p\u003e  \u003ch3\u003eSpecifications\u003c\/h3\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e \u003ctd\u003eHRV10-12\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e \u003ctd\u003e10 HP, 1,800 RPM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003ePump\u003c\/th\u003e \u003ctd\u003eRV30, belt driven, enclosed guard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAir delivery\u003c\/th\u003e \u003ctd\u003e34 CFM (see the note below)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e \u003ctd\u003e175 PSI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e \u003ctd\u003e120 gallons, horizontal, ASME coded\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e \u003ctd\u003e208 \/ 230 \/ 460 \/ 575V, 3-phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eConfiguration\u003c\/th\u003e \u003ctd\u003eSimplex\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e \u003ctd\u003eNEMA 1 magnetic, mounted as standard\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e \u003ctd\u003e3\/4\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eOverall length\u003c\/th\u003e \u003ctd\u003e71\"\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e \u003ctd\u003e895 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eAir dryer\u003c\/th\u003e \u003ctd\u003eNot fitted\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth scope=\"row\"\u003eElectronic drain valve\u003c\/th\u003e \u003ctd\u003eNot fitted\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e  \u003ch3\u003eA note about the air delivery figure\u003c\/h3\u003e \u003cp\u003eThe \u003cstrong\u003e34 CFM\u003c\/strong\u003e above is our catalogue's rating and it is the only delivery figure on this page. The manufacturer's own specification list gives two delivery values instead, one measured at 125 PSIG and one at 175 PSIG, and both are stored without a unit written next to the number. Both are slightly below the catalogue figure. We can tell you the factory document is the more conservative of the two sources; we are not going to reprint numbers whose unit our own data never states. If your tool load sits near the limit, ask us for the factory data sheet in writing before you commit — that gap is exactly where a shop discovers it is short of air.\u003c\/p\u003e  \u003ch3\u003eCertification, stated plainly\u003c\/h3\u003e \u003cp\u003eThis model's feature list makes two claims and both are useful: the receiver is ASME coded, with base-mount versions of the package specifically excluded from that, and the receiver meets California code. Nothing in our data claims a third-party safety listing for the packaged machine, so nothing of the sort is claimed here. Some insurers, fleet operations and local inspectors do require a particular listing on shop pressure equipment; if that is your situation, ask us to confirm in writing what documentation ships with this unit before you place the order.\u003c\/p\u003e  \u003ch3\u003eShipping and delivery\u003c\/h3\u003e \u003cp\u003eThis ships by freight to the lower 48 states, priced live at checkout because carrier rates change. You will need a way to get \u003cstrong\u003e895 lbs\u003c\/strong\u003e off a truck — forklift, dock, or a pallet jack with a level approach — or you can have it held for pickup at the carrier's terminal, which many buyers prefer for a machine this size. Residential addresses attract a residential fee. Inspect it before you sign: run your eye along the receiver for dents, check the pump, motor and starter for impact, and write anything you find on the delivery paperwork while the driver is still on site.\u003c\/p\u003e  \u003ch3\u003eWarranty\u003c\/h3\u003e \u003cp\u003eOur record for this model links to the store's \u003ca href=\"https:\/\/mechanicsuperstore.com\/pages\/warranty-claims\"\u003ewarranty claims page\u003c\/a\u003e but does not carry a term, so no period of cover is stated on this page — ask us for the current manufacturer terms in writing before ordering. Whatever they are, the same discipline protects them: if the machine faults, call us before anything comes apart. Diagnosing by disassembly ahead of the claim is the usual reason a sound claim ends up rejected.\u003c\/p\u003e","brand":"Gardner Denver","offers":[{"title":"Default Title","offer_id":54965125415251,"sku":"HRV10-12","price":2883.0,"currency_code":"GBP","in_stock":true}],"url":"https:\/\/progradewarehouse.com\/products\/champion-hrv10-12-air-compressor","provider":"PRO GRADE WAREHOUSE","version":"1.0","type":"link"}